REGULATIONS

Generalities:
• UNE-EN 947:1999 / UNE-EN 947:2000 ERRATUM - Hinged or pivoted doors – Determination of the resistance to vertical load. (It’s identical to EN 947:1998)
• UNE-EN 948:2000 - Hinged or pivoted doors – Determination of the resistance to static torsion. (It’s identical to EN 948:1999)
• UNE-EN 949:1999 / UNE-EN 949:2000 ERRATUM - Windows and curtain walling, doors, blinds and shutters – determination of the resistance to soft and heavy body impact for doors. (It’s identical to EN 949:1998)
• UNE-EN 950:2000 / UNE-EN 950:2002 ERRATUM - Door leaves – Determination of the resistance to hard body impact. (Tt’s identical to EN 950:1999)
• UNE-EN 951:1999 / UNE-EN 951:2000 ERRATUM - Door leaves – method for measurement of height, width, thickness and squareness. (It’s identical to EN 951:1998)
• UNE-EN 952:2000 - Door leaves – general and local flatness – measurement method. (It’s identical to EN 952:1999)
• UNE-EN 1192:2000 / UNE-EN 1192:2001 ERRATUM - Doors - Classifications of strength requirements. (It’s identical to EN 1192:1999)
• UNE-EN 1294:2000 - Door leaves - Determination of the behavior under humidity variations in successive uniform climates. (It’s identical to EN 1294:2000)
• UNE-EN 1522:1999 - Windows, doors, shutters and blinds – bullet resistance – requirements and classification. (It’s identical to EN 1522:1998)
• UNE-EN ISO 10140-1:2016 - Acoustics - Laboratory measurement of sound insulation of building elements - Part 1: Application rules for specific products (ISO 10140-1:2016). (It’s identical to EN ISO 10140-1:2016 and ISO 10140-1:2016)
• UNE-EN ISO 10140-2:2011 - Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation (ISO 10140-2:2010). (It’s identical to EN ISO 10140-2:2010 and ISO 10140-2:2010)
• UNE-EN ISO 10140-3:2011 - Acoustics - Laboratory measurement of sound insulation of building elements - Part 3: Measurement of impact sound insulation (ISO 10140-3:2010). (It’s identical to EN ISO 10140-3:2010 and ISO 10140-3:2010)
• UNE-EN ISO 10140-3:2011/A1:2015 - Acoustics - Laboratory measurement of sound insulation of building elements - Part 3: Measurement of impact sound insulation - Amendment 1 (ISO 10140-3:2010/Amd 1:2015). (It’s identical to EN ISO 10140-3:2010/A1:2015 and ISO 10140-3:2010/Amd.1:2015)
• UNE-EN ISO 10140-4:2011 - Acoustics - Laboratory measurement of sound insulation of building elements - Part 4: Measurement procedures and requirements (ISO 10140-4:2010). (It’s identical to EN ISO 10140-4:2010 and ISO 10140-4:2010)
• UNE-EN ISO 10140-5:2011 - Acoustics - Laboratory measurement of sound insulation of building elements - Part 5: Requirements for test facilities and equipment (ISO 10140-5:2010). (It’s identical to EN ISO 10140-5:2010 and ISO 10140-5:2010)
• UNE-EN ISO 10140-5:2011/A1:2014 (Version corrected in date 2016-11-08) - Acoustics - Laboratory measurement of sound insulation of building elements - Part 5: Requirements for test facilities and equipment - Amendment 1: Rainfall sound (ISO 10140-5:2010/Amd 1:2014). (It’s identical to EN ISO 10140-5:2010/A1:2014 and ISO 10140-5:2010/Amd.1:2014)
• UNE-EN ISO 12460-5:2016 – Wood derivatives - Determination of formaldehyde release - Part 5: Extraction method (called the perforator method) (ISO 12460-5:2015). (It’s identical to EN ISO 12460-5:2015)
• UNE-EN 13501-1:2007+A1:2010 - Fire classification of construction products and building elements - Part 1: Classification using data from reaction to fire tests (It’s identical to EN 13501-1:2007+A1:2009)
• UNE-EN 13501-2:2009+A1:2010 - Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services (It’s identical to EN 13501-2:2007+A1:2009)
• UNE-EN 14600:2006 - Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification. (It’s identical to EN 14600:2005)
• UNE-EN 15269-1:2011 - Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 1: General requirements. (It’s identical to EN 15269-1:2010)
• UNE-EN 15269-3:2016 - Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 3: Fire resistance of hinged and pivoted timber doorsets and openable timber framed windows. (It’s identical to EN 15269-3:2012)
• UNE-EN 15269-20:2010 - Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 20: Smoke control for hinged and pivoted steel, timber and metal framed glazed doorsets. (It’s identical to EN 15269-20:2009)
• UNE-EN 16034:2015 - Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics. (It’s identical to EN 16034:2014)
• UNE 56801:2008 - Wood door sets. Terminology, definitions and classification.
• UNE 56802:2012 - Wooden based door sets. Measures and tolerances.
• UNE 56803:2000 / UNE 56803:2001 ERRATUM - Door leaves. Complementary specifications.
• UNE 172402:2011 - Nursery school. Service management. General requirements.
• UNE-EN ISO 12460-5:2016 – Wood derivatives - Determination of formaldehyde release - Part 5: Extraction method (called the perforator method) (ISO 12460-5:2015). (It’s identical to EN ISO 12460-5:2015 - ISO 12460-5 - ISO/DIS 12460-5:2013

Essays:
• UNE-EN 179:2009 - Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods. (It’s identical to EN 179:2008)
• UNE-EN 1121:2000 - Doors - Behavior between two different climates - Test methods. (It’s identical to EN 1121:2000)
• UNE-EN 1125:2009 - Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods. (It’s identical to EN 1125:2008)
• UNE-EN 1154:2003 - Building hardware - Controlled door closing devices - Requirements and test methods. (It’s identical to EN 1154:1996 and EN 1154:1996/A1:2002)
• UNE-EN 1154:2003/AC:2006 - Building hardware - Controlled door closing devices - Requirements and test methods. (It’s identical to EN 1154:1996/A1:2002/AC:2006)
• UNE-EN 1158:2003 - Building hardware - Door coordinator devices - Requirements and test methods. (It’s identical to EN 1158:1997/A1:2002)
• UNE-EN 1158:2003/AC:2006 - Building hardware - Door coordinator devices - Requirements and test methods. (It’s identical to EN 1158:1997/A1:2002/AC:2006)
• UNE-EN 1191:2013 - Windows and doors - Resistance to repeated opening and closing - Test method. (It’s identical to EN 1191:2012)
• UNE-EN 1634-1:2016+A1:2018 - Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows. (It’s identical to EN 1634-1:2014)
• UNE-EN 1634-2:2010 - Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterization test for elements of building hardware. (It’s identical to EN 1634-2:2008
• UNE-EN 1634-3:2006 - Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 3: Smoke control test for door and shutter assemblies. (It’s identical to EN 1634-3:2004 and EN 1634-3:2004/AC:2006)
• UNE-EN 1935:2002 - Building hardware - Single-axis hinges - Requirements and test methods. (It’s identical to EN 1935:2002)
• UNE-EN 1935/AC:2004 - Building hardware - Single-axis hinges - Requirements and test methods. (It’s identical to EN 1935:2002/AC:2003)
• UNE-EN ISO 11925-2:2011 - Reaction to fire tests - Ignitability of products subjected to direct impingement of flame - Part 2: Single-flame source test (ISO 11925-2:2010). (It’s identical to EN ISO 11925-2:2010, EN ISO 11925-2:2010/AC:2011, ISO 11925-2:2010 and ISO 11925-2:2010/Cor.1:2011)
• UNE-EN 12209:2017 - Building hardware - Locks and latches - Mechanically operated locks, latches and locking plates - Requirements and test methods. (It’s identical to EN 12209:2003)
• UNE 56850:1988 - Method of testing doors. Water immersions test for door leaves. (Not equivalent NF P 20-522)
• UNE 56851:1917 - Method of testing doors. Test of screw withdrawal. (Not equivalent NF P 20 524)
• UL 10C: 2016 - Standard for safety for positive pressure fire tests of door assemblies.

Top